1
2A Note
If ELEMENT-EL Baby 4 is used, always apply the fixing adhesive COL-AK over the full surface using a toothed trowel. This technique is also possible for thicker panels, depending on the substrate.
2B Note
When using ELEMENT-EL ≥ 6 mm, apply the fixing adhesive COL-AK pointwise on one side using dots of adhesive (8 – 10 pcs. per m2). Before applying adhesive pre-pierce the holes for the hammer fix plugs FIX-FID or FIX-KSD.
3
Position the ELEMENT construction panels at the top edge of the old tiling (knock off obstructive plaster clots before beginning, if necessary) and press to the wall.
4
Press on with the level and spirit level and align vertically and flush with the old tiling. Also pay attention to the horizontal alignment of the ELEMENT construction panels to one another!
5
Dowel after approx 3 hours. Select the correct dowel pins or fastening set to correspond with the existing masonry and plaster thickness. Pay attention to water and power lines! We recommend 6–8 dowels per m2. TIP: Pre-drill dowel holes
6
Reinforce the transition from the ELEMENT to the old tiling with glass fibre reinforcement strips ARM-100 SK.
7
Level out the glass fibre reinforcement strips, element joints and dowel pin heads with COL-AK. The surface is now ready for tiling. Further requirements (e.g. sealing for wet loads) must be taken into consideration in accordance with national directives.
- Practical instructions
-
The basis
Quality with the environment in mind
Working with hard foam support elements
The tools
Recommended cutting techniques for the ELEMENT construction panel
LUX ELEMENTS®- ELEMENT EL
LUX ELEMENTS®- ELEMENT-SL / SQ
Bending radii, slit spacings, dimensions of pre-slit hard foam
Processing instructions with slit panels
LUX ELEMENTS®- ELEMENT-VK
General processing instructions
Processing tips
The following materials are suitable for cladding hard foam support elements
- Application areas
-
Walls in interior areas
Attaching to masonry, concrete or plaster with mortar
Wall levelling over existing tile coverings
The multi-functional construction panel: application on the wall (example)
Application on free-standing metalsupports
The multi-functional construction panel: application on metal stud frame (example)
Wall-mounted elements
The creation of a levelling construction
Planking of a support construction
Floor applications
Application on beton or screed
Application on wooden floor boards
Application on the floor
The multi-functional construction panel: on mineral substrate (example)
Floor shower base
- Construction & design
-
With straight panels
Partition walls or room dividers
With slit panels
- Practical examples
- Product
- Datasheets
-
LUX ELEMENTS®- ELEMENT-EL (411 KB) LUX ELEMENTS®- ELEMENT-SL/SQ 30, 50, 80 (134 KB) LUX ELEMENTS®- ELEMENT-VK (411 KB)
- Safety Data Sheets
-
- Installation instructions
- Product & packaging specs
- Systemcomponents
-
The proven and tested system components are fully matched to the processing of the hard foam support elements. The specially developed accessories ensure trouble-free working and high processing reliability.
LUX ELEMENTS®- ARM: Reinforcement fabric LUX ELEMENTS®- COL: Adhesives LUX ELEMENTS®- DRY: Sealing filler and sealing tapes LUX ELEMENTS®- FIX: Fastening sets and plugs/exterior LUX ELEMENTS®- MONT: Mounting aids
Before printing a pdf file, please check if this is really necessary.
Environmental protection concerns us all.
To view the PDF files, you will need Acrobat Reader that you can download here free-of-charge. This program will enable you to open, view and print out these documents in PDF format.